Resources › Tanks & Systems
Managing Diesel Across Multiple Sites: Monitoring, Automated Dispensing and Reconciliation
Every extra site adds a tank nobody is standing next to. The answer is not more site visits. It is data that comes to you.
- Monitoring
- Dispensing
- Reconciliation
- Rollout
The best way to manage diesel across multiple sites is to make every site report the same three things to one place: how much fuel is in each tank, who drew fuel and how much, and how much was delivered. Automatic tank gauging sends tank levels remotely over mobile or LoRa networks, with solar or battery power where there is no mains. A fuel management system at each dispensing point releases fuel only to an authorised fob, card, PIN or vehicle tag and records every litre against a vehicle and driver. With deliveries recorded as well, each site can be reconciled the same way: opening level, plus deliveries, minus litres dispensed, should equal the closing level. Any gap shows up per site, per week, instead of in a year-end stocktake. Use the same identification method and reporting across every site so drivers and data move between them without change.
Managing one tank is mostly a matter of walking out to it. Managing ten, spread across depots, quarries, project sites and regional yards, is a different job. Nobody can dip every tank, nobody sees every refuel, and by the time the monthly fuel invoice arrives the question of where it all went has no answer.
This guide is about that multi-site problem: getting a single view of stock, use and losses across a network of sites. Choosing a fuel management system in the first place is covered in A-FLO's fuel management systems buyer's guide.
10 FLUIDLEV tank gauging units that can report through a single gateway
1 to 4 Hoses controlled by one FLUIDTRACK fuel management system
3 Power options for remote equipment: 240V mains, 12 or 24V DC, and solar
Why Multiple Sites Are Harder Than One
- No one sees the tank. Levels are checked when someone remembers, so low stock is noticed late and deliveries are ordered in a hurry.
- No one sees the nozzle. Fuel drawn at a remote yard is recorded on paper, if at all, and rarely against the right vehicle or job.
- Every site does it differently. One depot uses keys, another a logbook, another nothing, so the figures cannot be compared.
- Losses hide in the total. A slow leak, an overfill or fuel going into private vehicles at one site disappears into the company-wide consumption figure.
The fix is the same at every site: measure the tank, control and record the nozzle, record the delivery, and bring all of it into one report.
Remote Tank Monitoring for Every Site
Automatic tank gauging puts a probe in the tank that measures the level continuously and reports it remotely, so stock at every site can be seen from one screen.
| Site condition |
What suits it |
| Mains power and good mobile coverage |
A standalone gauge reporting over the mobile network, powered from 240V |
| No mains power |
Solar or battery powered gauging, such as the FLUIDLEV GSM33 or LoRa battery nodes |
| Poor mobile coverage |
LoRa nodes on the tanks, reporting to a gateway placed where the signal is better |
| Several tanks in one yard |
One gateway collecting several tanks, which means fewer connections to manage. A FLUIDLEV gateway takes up to 10 units |
| Tall or deep tanks |
A probe long enough for the tank, with 3, 6 and 10 metre options |
A-FLO supplies the LEVELTRACK 360 and FLUIDLEV automatic tank gauging ranges. With levels reported, deliveries can be scheduled from real stock rather than a guess, and a level that falls overnight with no dispensing recorded is visible the next morning.
Automated Dispensing at Each Site
Tank levels show how much fuel left. A fuel management system shows where it went. At each dispensing point, fuel is released only to an authorised identifier and every transaction is recorded.
Depots and mine sites
FLUIDTRACK
FLUIDTRACK systems control one to four hoses, come with NFC fob keys, run on 240V or 12 or 24V DC, and offer a range of ID options and third-party integrations, with a tank gauging module available.
Existing pumps and remote tanks
FLUIDLINK
FLUIDLINK systems can be retrofitted to an existing pump or bowser. The FLUIDLINK MICRO mounts on a surface or tank and is available in 12 to 24V, 240V and solar versions.
Identification
Fob, card, PIN or tag
Drivers and machines are identified by key fob, RFID card, PIN or vehicle tag. Using the same method across every site lets a driver refuel anywhere in the network with the same credential.
A-FLO's fuel management systems range scales from a single controlled dispensing point to a networked multi-site operation.
Reconciling Fuel Site by Site
Once each site measures its tank and records its dispensing, it can be reconciled the same simple way.
The reconciliation
Opening tank level, plus litres delivered, minus litres dispensed, should equal the closing tank level. Run it for each site over the same period, weekly or monthly, and the difference is the fuel that cannot be accounted for.
- Record every delivery. Enter the delivered volume from the docket, and check it against the level rise the gauge recorded.
- Use the same period at every site. Comparing a weekly figure at one depot to a monthly figure at another hides problems.
- Set a tolerance. Small differences come from temperature and meter accuracy. Agree what size of gap triggers a look.
- Investigate by site. A gap at one site points to that site's tank, meter, fittings or access control, not the whole network.
Common causes of a gap are an unrecorded refuel, a delivery that was not entered, a leak, a meter that needs calibrating, or fuel drawn without an identifier. For keeping the stock itself in condition, see water in diesel.
Scheduling Deliveries Across the Network
With every tank reporting, deliveries can be planned for the network rather than site by site.
- Order on level, not on a calendar. Set a reorder level for each tank based on its daily use and the supplier's lead time.
- Combine drops. Sites on the same route that are approaching their reorder levels can be filled on one run.
- Make sure there is room. Check each tank can take a full delivery before the truck arrives.
- Size tanks to the delivery pattern. A site that keeps needing urgent deliveries may need more capacity. A-FLO's guide to choosing the right size and type of tank covers sizing.
Rolling Out Across Your Sites
List every site and tank
Record the tank size, fuel type, number of hoses, power, mobile coverage and who refuels there.
Decide what the reports must answer
Loss prevention, fuel by cost centre or project, compliance records, or all three. This drives what is recorded at every transaction.
Standardise identification
Choose one method for drivers and vehicles across the network, so credentials work at every site.
Start with the biggest or least visible site
The site with the most fuel, or the one furthest from anyone's view, usually shows the clearest result first.
Retrofit where you can
Existing tanks and pumps can usually take gauging and fuel management hardware without replacing the tank.
Review the first reconciliations
The first weeks of data usually show where the gaps are. Fix those, then roll on to the next sites.
A-FLO supplied a Fueltainer FT56/7 diesel and AdBlue combination tank for Toll, one of Australia's largest transport and logistics operators. Other projects are listed under tanks and systems case studies, and A-FLO's service and maintenance team covers fuel management and tank gauging across Australia.
What Goes Wrong
- Different systems at every site. The data cannot be combined, and drivers need a different credential at each yard.
- Gauging without dispensing records. The level drops, but there is no way to say who took the fuel.
- Dispensing records without deliveries. Without delivered volumes, a site cannot be reconciled.
- Nobody reads the report. Assign someone to review the reconciliation for each site, on a fixed day.
- Ignoring the remote sites. The sites with the least supervision usually have the biggest gaps.
- Shared fobs or PINs. One credential used by several drivers defeats the record.
Frequently Asked Questions
What is the best way to manage diesel across multiple sites?
Have every site report tank levels, dispensing and deliveries to one place. Fit automatic tank gauging to each tank, a fuel management system at each dispensing point, record every delivery, and reconcile each site over the same period using the same identification and reporting across the network.
What are automated fuel dispensing systems?
They are fuel management systems that release fuel only to an authorised key fob, RFID card, PIN or vehicle tag, and record the volume, vehicle, driver and time of every transaction. A-FLO supplies the FLUIDTRACK and FLUIDLINK ranges in Australia.
Can fuel management be integrated with fuel storage?
Yes. Fuel management hardware can be fitted to a tank's pump and dispensing equipment, and automatic tank gauging can be added to the tank, so stock and dispensing are recorded together. Existing tanks and pumps can usually be retrofitted.
How do you reconcile diesel at each site?
Take the opening tank level, add the litres delivered, subtract the litres dispensed, and compare the result with the closing level. Do this for every site over the same period. A difference beyond an agreed tolerance is fuel that cannot be accounted for and should be investigated at that site.
Can tank levels be monitored at remote sites with no power?
Yes. Solar or battery powered gauges report levels over the mobile network, and where coverage is poor, LoRa nodes can report to a gateway placed where the signal is better.
Can drivers use the same fob at every site?
They can if every site uses the same fuel management platform and identification method. Standardising this across the network is one of the first decisions in a multi-site rollout.
Do I need to replace my tanks to add fuel management?
Usually not. Fuel management control hardware and tank gauging can generally be fitted to existing tanks, pumps and bowsers.